Abstract
This study exhibits a simplified direct power control strategy based on the model predictive control for grid-tie inverters. To solve the problem of the variable switching frequency in the classical finite control set model predictive control (FCS-MPC), we combined the inverse predictive model and space vector modulation to calculate the desired inverter voltage. Furthermore, the computational burden is reduced thanks to the elimination of the optimization loop. A comparative study indicated that the proposed approach achieved better steady-state control performance concerning the low total harmonic distortion of the current model compared with the traditional FCS-MPC while guaranteeing a fast dynamic response. The effectiveness and feasibility of the proposed method were confirmed via simulations and experimental results.
References
- - Pham Viet Tuan, Faculty of Physics, University of Education, Hue University. Email: phamviettuan@gmail.com
- - Ha Xuan Vinh, Hue Industrial College. Email: hxvinh@hueic.edu.vn

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Copyright (c) 2024 Array